AI Electrical Inspection for Electricians & Contractors

    See the NEC violations your photo can show.

    Photograph a service panel, junction box, or rough-in with your phone. No Sparks lists apparent NEC violations that are visible in the image, then ties each finding to an exact article, official title, observed condition, and reason.

    Exact article references
    Visible evidence only
    Mobile jobsite ready
    LIVE INSPECTION PREVIEW
    NEC 2026
    Electrical panel inspection
    1 Violation Listed
    NEC 110.26(A)(1)Article reference

    Working space condition visible in front of panel.

    Target: 200A Service EquipmentTry with your photo
    FIELD WORKFLOW

    How No Sparks Works On The Job

    Built for rapid use on smartphones in tight basements, attics, and commercial equipment rooms.

    01

    Snap or Upload Photo

    Open your camera inside No Sparks. Photograph the service panel interior, rough-in wire run, subpanel bonding, or junction box.

    Works on iOS and Android browsers
    02

    Compare Visible Conditions

    The scan inventories the visible photo region by region, then compares each concrete condition with the fixed NEC 2026 reference. Unresolved concerns stay visible for field verification.

    Fixed reference: NEC 2026
    03

    Read Article & Evidence

    See the exact article, official title, visible condition, and explanation for each apparent violation. Copy the citation for your field notes.

    One-click citation copy
    SAMPLE INSPECTION OUTPUT

    An article-first photo report

    Each listed finding connects one visible condition to a specific NEC article. When a visible concern needs more evidence for an article, it stays in a separate verification section instead of disappearing or turning into a guess.

    SAMPLE SCAN RESULT
    NEC 2026 Reference

    Target: Residential Main Service & Branch Wiring. Two apparent violations listed.

    Test with your own photo
    #1
    NEC VIOLATION
    NEC 110.26(A)(1)

    Working Spaces Depth and Clearances

    Visible Condition

    Storage materials and structural framing are visible within the working space directly in front of the 200A service panelboard.

    Why This Appears To Violate The NEC

    The cited section requires a clear working space in front of equipment so it can be operated and maintained safely. The obstruction shown occupies that required approach area.

    #2
    NEC VIOLATION
    NEC 314.17(B)(2)

    Insulated Bushings and Cable Protection in Metal Enclosures

    Visible Condition

    The photo shows a metal knockout entry where the cable sheath meets an unprotected sharp edge, with no visible approved connector or insulating bushing.

    Why This Appears To Violate The NEC

    The cited section requires the cable entry into a metal enclosure to protect the sheath and conductors from abrasion. The visible entry does not show that protection.

    Common NEC Review Areas

    Focused on common inspection questions across residential and commercial jobs.

    NEC 110.26

    Working Space & Clearances

    Looks for visible storage obstructions, headroom issues, and door swing interference in front of electrical equipment.

    NEC 314.16

    Box Fill & Volume Limits

    Reviews visible conductor counts, device yokes, internal clamps, and grounding conductors in accessible boxes.

    NEC 250.24 / 250.50

    Grounding & Neutral Bonding

    Reviews visible bonding jumpers, electrode connections, and neutral isolation details when the photo shows them.

    NEC 210.8 / 210.12

    GFCI & AFCI Protection

    Looks for visible protection devices when the location and circuit context can be established from the image.

    NEC 300.4 / 314.17

    Cable Clamps & Knockout Bushings

    Identifies visible sharp knockout edges, missing grommets, and unsecured cable entries.

    NEC 408.4 / 110.3(B)

    Panel Directory & Breaker Class

    Reads visible circuit identification, classified breaker markings, and tandem breaker fitment when legible.

    FUTURE ROADMAP

    Field Calculators & Wiring Charts Coming Next

    We are expanding No Sparks into the definitive pocket companion for electricians. Upcoming tools include automated conduit fill calculators, 3% voltage drop charts, motor FLA lookups, and team-wide monthly subscription seats.

    Start Scanning Photos Free
    Build the field reference one job at a time
    Built for the next photo on the jobsite

    Ready for the next jobsite photo?

    Photograph panels, junction boxes, and rough-ins, then see which NEC articles connect to visible conditions. Your local AHJ still makes the final determination.

    Legal & Safety Notice: No Sparks Code Corrections is an AI-powered field reference tool. It does not replace an official inspection by your local Authority Having Jurisdiction (AHJ). Always verify requirements with local municipal codes and amendments, and ensure work is performed by licensed electrical professionals.

    No Sparks circular logo
    NO SPARKS CODE CORRECTIONS

    The AI-powered photographic inspection companion for licensed journeymen, master electricians, general contractors, and trade apprentices. Spot code violations before the city inspector walks the jobsite.

    NFPA 70 / NEC ReferenceNEC 2026 Reference

    Coming Soon

    Conduit Fill & Voltage Drop

    Interactive wire ampacity charts, motor full-load tables, and multi-gang box volume calculators.

    Field Pro Subscription Phase
    © 2026 No Sparks Code Corrections. Built for field professionals.
    NEC® is a registered trademark of the NFPA
    Buildy Logo
    Built with Buildy.ai